Precession vortex flow sensor is a sensor widely used in various gas flow measurement in petroleum, chemical industry, electric power, metallurgy, urban gas supply, etc. The precise use of precession vortex flow sensor must comply with the following five requirements, so as to ensure the measurement Accuracy.
1, accurate selection
   Precession vortex flowmeter is widely used in natural gas, gas and other occupations, stable performance, accurate measurement, and convenient installation. In the case that it has been determined that the precession vortex flowmeter is selected, it is immediately followed by the flow sensor standard and its supporting components. The choice is crucial. In a word, we must use good talents. To this end, two basic principles should be grasped during the selection process; namely, one must ensure the use of precision, and the other must ensure production safety. To do this, three selection parameters must be implemented, namely, the maximum, minimum, and common instantaneous flow rates in the near-term and long-term, the planned pressure of the measured medium, and the operating pressure.
2, using the former calibration
On the one hand, considering the current on-the-spot verification of such flow sensors, there are still such difficulties. In addition, if the purpose of the purchase is to prepare this kind of flow sensor for use in more important measurement occasions, such as high-volume trade measurement or measurement cementation, the measurement points are more prominent, and the use of the site does not have the flow online calibration conditions. , In this case, it is premature to conclude that the flow sensor is fully qualified only by the confirmation of a factory shipment that was supplied by the manufacturer at the time of purchase. Therefore, in order to ensure the reliability and accuracy of the measurement results of the flow sensor in the future operation process, it is necessary to send the flow sensor to the system with the verification ability and talent in this area before the formal installation. .
3, do a good job of technical devices
Although this type of flow sensor does not have a lot of special requirements for the technical device and the operating environment, there is a commonality in any kind of flow measurement appearance that prevents vibration and high temperature environments from disturbing the components with the off-flow state and keeping the flow sensor as much as possible. Smooth and straight inner wall of the straight pipe before and after, to ensure that the measured medium is a clean single-phase fluid.
4, strengthen the post-processing
Although the precession vortex flowmeter has many features of active disposal and micro power consumption, it needs to be strengthened after it is put into operation. For example, in order to ensure the accuracy and reliability of the flow sensor for a long time, the system should be calibrated regularly, the header data should be copied, the media parameters should be replaced, the battery status should be checked from time to time, and the flow sensor coefficients and seals should be checked.
5, pay attention to internal protection
If the measuring chamber and its components of the flow sensor are regularly viewed or cleaned due to the contamination of the gas or other reasons, there is one point that must be paid special attention to: the eddy attack body and the guiding fluid of the same standard precession vortex flow sensor. The isocenter components cannot be exchanged, otherwise, the external metering coefficients must be calibrated from the beginning and the temperature and pressure sensors provided must be calibrated.